Installing the SafeView inlet
Swap out your old inlet in about 30 minutes with basic hand tools.
Applies toSafeView Inlet
Before you start
Unplug the RV from all power and turn the RV’s main breaker off. If you’re unsure, have an electrician do it.
Tools: Phillips screwdriver, tape measure, utility knife, wire cutters.
- Remove the four screws and pull the old inlet out. Disconnect its wires.
- Hold the SafeView in the hole to check the fit. Mark and drill new screw holes if needed.
- On the SafeView, loosen the screw on the rear housing and remove the housing. On the 30A, turn it counterclockwise to take it off.
- Remove the cable bushing. Keep it, you may need it later.
- Strip 1 5/8 in of the cable’s outer jacket and 5/8 in from each wire. The copper should be shiny with all strands intact.
- Feed the cable through the rear housing.
- Connect each wire to the terminal of the matching color, then tighten. Don’t overtighten.
- 30A: white = neutral, green = ground, red = line. Tighten to 35–40 in-lb.
- 50A: white = neutral, green = ground, red = line 1, black = line 2. Tighten to 45–50 in-lb.
- Reattach the rear housing and tighten its screw (5.5–6.5 in-lb).
- Tighten the strain relief clamp around the cable (5.5–6.5 in-lb). Use the bushing if the fit is loose.
- Set the inlet in the hole and secure it with the four screws.
- Check that everything is tight, then press the cover down.
- Turn power back on and check the lights.
Full guides with drawings: 30A installation guide · 50A installation guide